Troubleshooting
›
Tapping
›
Reground Taps
›
Too Large Thread
Thread produced is too large
BACK
Possible causes
Solution
burrs
remove burrs
cutting edge geometry (chamfer lead, rake-, chamfer-, spiral point angle) not retained
- observe technical specifications when regrinding.
- observe regrinding instruction